EZ Mount Network Shelf 2 Specification Sheet
Complete EZ Mount Product Index
EZ Mount Network Shelf
EZ Mount Swivel Bracket
EZ Mount Extention Brackets
EZ Mount Wall Swivel Bracket
EZ Mount Wall Swivel Bracket Shelf
EZ Mount Secur-A-Shelf
iNNOdata EZ Mount Story
Customer Stories
This years show schedules
Phone, FAX, e-mail and Inquiry Form
Distributor and shipping information.
 P/N:  EZMS-2
Specifications
Dimensions 19 3/16" Wide x 22" Deep x 9" High (Shelf 20 1/2" Deep).
Compatible With (but not included) One or two 12 or 24 port patch panels or one 48 port patch panel. (To expand two (2) RMS, see "OPTION" below.)
Weight Spec. When properly mounted will support up to 100 lb.
Power Strip (not included) Mounting holes provided on underside for one (1) rack mount power strip.
Mounting Holes 6 3/4" key-hole mounting holes for 16" on center mounting.  8 mounting slots on 18 1/2" centers for mounting on relay rack.
Included with Shelf Package of eight (8) 10-32 screws, one (1) ground screw, four (4) 6" Velcro strips (24" total), Blank Plate, Mounting Template.  Slots provided on shelf deck for equipment tie down with Velcro straps (Not included).
Option EZ Mount Swivel Bracket to expand two (2) rack spaces (P/N:  EZMBS).
Warranty Against defects in materials and manufacturing.
Instructions for Use
To mount the shelf for initial installation of network components: Mark wall w/template.                                                                                                                                                                           Mount shelf on wall with four screws.                                                                                                                                                                                                                                                                                                                                                            Attach patch panel(s), blank plate, and power strip to shelf as desired, using 10-32 screws provided.                                                                                                                                                                                Insert Velcro (included) in side slots provided to manage station cables (see diagram below).                                                                                                                                                                                                                 
To rotate patch panel(s) for easy wire connections: Pull plunger assembly on each side of shelf AND turn counterclockwise until the plunger locks open.                                                                                                                                                                Rotate top of patch panel downward until backside is exposed.                                                                                                                               To release plunger assemblies, turn clockwise and lock patch panel in reverse position.                                                                                                                   Position wire manager as desired.                                                                                                                                 Allow enough slack when installing cable to allow patch panel to swivel into its original position. 
To return patch panel(s) to functional position: Pull plunger assembly on each side of shelf AND turn counterclockwise until the plunger locks open.                                                                                                                                                                                                                                                       Rotate bottom of patch panel upward until front of patch panel is exposed.                                           To release plunger assemblies, turn clockwise and lock patch panel in functional position.                                                      
NOTE:  Patch Panel(s) and Power Strip are USER Supplied.

 